Case study of 52 story tower

Case study of 52 story tower

SI.NO.DESCRIPTIONGEOMETRY
1UsagesResidential & Commercial
2Height of Building200 m
3No. of StoriesG+50
4Storey Height3.9m
5Type of StructureDual Framing System
6Location
7Dead LoadFrame, Shell & Cladding
8Live Load5 KN/m²
9Load CombinationGravity + Lateral Loads
10Types of AnalysisStatic & Dynamic analysis FEM, Modal analysis, P-∆
11Code BasedAmerican Standards

CODAL PROVISION

Drift (Full structure)

Max Drift = Etabs drift *0.7*R  Limitation

<0.02 in case T >0.7

<0.025in case T<0.7

Also should be checked for per floors

Story Drift = Etabs drift *0.7*R* h(floor height)  Limitation

<0.02hin case T>0.7

<0.025h in case T<0.7

Wind Limitation

Total Height /500 = maximum allowed displacement  Response spectrum

Scale factor

Base shear of EQx/ Base shear of Spec x =

scale factor of spec x and 0.3of scale factor for Spec y

Base shear of EQy/ Base shear of Spec y =

scale factor of spec y and 0.3of scale factor for Spec x

SEISMICWIND
98.299mm MAX.43.26mm MAX.