Case study of 52 story tower

SI.NO. | DESCRIPTION | GEOMETRY |
1 | Usages | Residential & Commercial |
2 | Height of Building | 200 m |
3 | No. of Stories | G+50 |
4 | Storey Height | 3.9m |
5 | Type of Structure | Dual Framing System |
6 | Location | |
7 | Dead Load | Frame, Shell & Cladding |
8 | Live Load | 5 KN/m² |
9 | Load Combination | Gravity + Lateral Loads |
10 | Types of Analysis | Static & Dynamic analysis FEM, Modal analysis, P-∆ |
11 | Code Based | American Standards |

CODAL PROVISION
Drift (Full structure)
Max Drift = Etabs drift *0.7*R Limitation
<0.02 in case T >0.7
<0.025in case T<0.7
Also should be checked for per floors
Story Drift = Etabs drift *0.7*R* h(floor height) Limitation
<0.02hin case T>0.7
<0.025h in case T<0.7
Wind Limitation
Total Height /500 = maximum allowed displacement Response spectrum
Scale factor
Base shear of EQx/ Base shear of Spec x =
scale factor of spec x and 0.3of scale factor for Spec y
Base shear of EQy/ Base shear of Spec y =
scale factor of spec y and 0.3of scale factor for Spec x
SEISMIC | WIND |
98.299mm MAX. | 43.26mm MAX. |